 DS1205S
DS1205S MultiKey Chip
FEATURES
PIN ASSIGNMENT
VCCI NC RST DQ NC 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 VCCO NC I/O GND NC DQOE NC BAT
* Three
each
secure read/write data partitions of 384 bits
* One non-secure read/write data partition of 512 bits * Secure data cannot be deciphered by reverse engineering
* Guaranteed
number
unique, 48-bit, laser etched serial
CLK NC GND
* 64-bit password and I.D. fields provide positive identification and security for each secure data partition
* Maximum data transfer rate of 2 million bits/second * Low-power CMOS circuitry * Access via 3-wire or 1-wire interface * Applications include proprietary data, financial transactions, secure personnel areas, and systems access control
DS1205S 16-Pin SOIC (300 mil) See Mech. Drawings Section
PIN DESCRIPTION
VCCI RST DQ CLK GND BAT DQOE I/O VCCO - - - - - - - - - +5V Supply (Battery Backup Mode) Reset (3-Wire) Data (3-Wire) Clock (3-Wire) Ground Battery (+) (Battery Backup Mode) Data Available (3-Wire) Data I/O (1-Wire) Battery (+) (Battery Powered Mode)
DESCRIPTION
The DS1205S MultiKey Chip is an enhanced version of the DS1204U Electronic Key which has both a standard 3-wire interface (data, clock, and reset) and a 1-wire interface. The DS1205S MultiKey has three secure read/ write subkeys which are each 384 bits in length. In addition, there is a 512-bit read/write scratchpad which can be used as a non-secure data area or as a holding register for data transfer to one of the three subkeys. Each subkey within the part is uniquely addressable on byte boundaries.
OPERATING MODES
There are two modes of operation for powering the DS1205S MultiKey Chip. In the Normal Mode (Battery Backup), VCC power is supplied to the part on the VCCI pin, while the battery backup source is applied to the BAT pin. In this mode of operation, the chip supply is switched internally between VCCI and BAT (depending on which is higher) and this level is presented internally to the VCCO pin. In the Battery Operate Mode, the battery supply is connected directly to the VCCO pin while the VCCI and BAT pins are grounded.
021798 1/17
DS1205S
INTERFACES
Two interfaces to the DS1205S are provided. The 1-wire interface requires a 1-wire I/O command for addressing the device. An additional function command word is then passed through the 1-wire interface to access the various DS1205S functions. The 3-wire interface (data (DQ), reset (RST), and clock (CLK)) requires only the function command word. The four 1-wire I/O commands that deal with the unique lasered ROM are available only through the 1-wire interface. All other functions are available through either interface.
FUNCTIONS
A command word written written to the DS1205S MultiKey specifies the operation to be performed and the partition to be operated on. There are two classes of functions available. One class includes operations on the read/write secure partitions. The other class includes operations on the read/write scratchpad (Figure 1).
COMMAND OPERATIONS Figure 1
COMMAND WORD (24 BITS)
SECURE READ/WRITE
SCRATCHPAD READ/WRITE
SUBKEY 0
SUBKEY 1
SUBKEY 2
SCRATCHPAD
The 24 bit function command word is organized into three fields of eight bits each. These one byte fields include the function to be performed, the memory partition to be accessed and the starting byte address for the data transfer operation. The starting byte address and the partition codes are required to be given in both real and complement form. If these values do not match, access to the part will be denied (Figure 2). The function command word is presented to the DS1205S LSB first. The first byte contains the 8-bit
function code that defines which of the six valid function codes is to be executed. Each function code is valid for only certain partition and starting address combinations. Figure 3 illustrates the valid partition code, starting address and function code combinations. The second byte consists of the 2-bit partition code, identifying which partition is being accessed, and the 6-bit starting byte address, which specifies where to start the access of the given partition. The third byte consists of the complement of the 2-bit partition code and the complement of the 6-bit starting byte address.
021798 2/17
DS1205S
COMMAND WORD STRUCTURE Figure 2
MSB (KK)C(AAAAAA)C (KK) (AAAAAA) LSB FFFFFFFF
(KK) =
Two-bit number specifying which partition is to be accessed. 00 specifies subkey 0. 01 specifies subkey 1. 10 specifies subkey 2. 11 specifies the scratchpad. Complement of (KK) on a bit-by-bit basis. If the numbers are not complements the command word is invalid and no action will be taken. Address field containing address bits that define the starting byte address of the partition to be accessed. Complement of (AAAAAA) on a bit-by-bit basis. If the numbers are not complements the command word is invalid and no action will be taken. Function code field. Specifies the action to be taken.
(KK)C = (AAAAAA) =
(AAAAAA)C = FFFFFFFF =
LOCATIONS, AND FUNCTION CODES FOR EACH COMMAND WORD Figure 3
COMMAND Set Scratchpad Get Scratchpad Set Secure Data Get Secure Data Set Security Match Move Block VALID PARTITION CODE KK 11 11 00, 01, 10 00, 01, 10 00, 01, 10 00, 01, 10 VALID BYTE ADDRESS AAAAAA 0 - 63 0 - 63 16 - 63 16 - 63 000000 000000 VALID FUNCTION CODE FFFF FFFF 1001 0110 0110 1001 1001 1001 0110 0110 0101 1010 0011 1100
SECURE PARTITION COMMANDS
Each of the three secure partitions within the DS1205S MultiKey is comprised of a 64-bit I.D. field, a 64-bit security match code and a 384-bit secure data field (Figure 4). The three commands that operate on the secure partitions are:
1) Set Security Match 2) Set Secure Data 3) Get Secure Data As a guard against attackers, the security match code can never be read. Similarly, tampering through reprogramming will immediately clear the entire secure partition.
SECURE PARTITION ORGANIZATION Figure 4
0 ID FIELD 64 BITS 7 8 15 16 63 BYTES
SECURITY MATCH FIELD 64 BITS
SECURE DATA FIELD 384 BITS
021798 3/17
DS1205S
SET SECURITY MATCH
The Set Security Match command is used to enter data into the I.D. and security match fields of the selected secure partition. The DS1205S will respond to the command by outputting the 64-bit I.D. field of the selected secure partition. The next 64 clock cycles are used to echo the I.D. field back to the DS1205S. Upon receipt of the correct I.D., the DS1205S MultiKey will erase the contents of the selected secure partition. The part is then ready to receive the the new 64-bit I.D. and the 64-bit security match code. The flow sequence is shown in Figure 5.
partition is byte addressable. The scratchpad can be used to store unsecured data or it can act as a staging area to build and verify data structures to be transferred to a secure partition. The three commands that operate on the read/write scratchpad are: 1. Set Scratchpad Data 2. Get Scratchpad Data 3. Move Block
SET SCRATCHPAD DATA
The Set Scratchpad Data command is used to enter data into the DS1205S MultiKey scratchpad. The command word must specify the starting byte address for the data transfer. Valid byte addresses are 0 through 63. The DS1205S MultiKey will write data to the scratchpad until byte 63 has been written or until the RST line goes to a logic low level. The flow sequence is shown in Figure 8.
SET SECURE DATA
The Set Secure Data command is used to write data into the selected secure partition. After the command is received by the DS1205S, the 64-bit I.D. field of the selected secure partition is output. The next 64 bits of input comprise a password that must match the security match code of the selected secure partition. If the password and the security match are identical, data is written to the secure data field starting at the address specified in the command word. If the password and the security match code are not identical, the DS1205S will terminate the transaction immediately. The flow sequence is shown in Figure 6.
GET SCRATCHPAD DATA
The Get Scratchpad data command is used to retrieve data from the 512-bit scratchpad. The command word must specify the starting byte address for the data retrieval. Valid byte addresses are 0 through 63. The DS1205S MultiKey will retrieve data from the scratchpad until byte 63 has been read or the RST line goes to a logic low level. The flow sequence is shown in Figure 9.
GET SECURE DATA
The Get Secure Data command is used to retrieve data from the selected secure partition. After the command word is received by the DS1205S, the 64-bit I.D. field of the selected secure partition is returned. The next 64 bits are the password being written to the DS1205S. If the presented password and the security match code of the selected secure partition are identical, the DS1205S will output the contents of the secure data field starting from the byte specified in the command word. If the presented password is not identical to the security match code, the DS1205S MultiKey will use the password as a "seed" for its internal random number generator. This results in a repeatable, seemingly valid yet false response to the invalid password. The flow sequence is shown in Figure 7.
MOVE BLOCK
The Move Block command is used to transfer data, which has been previously entered into the scratchpad and verified, to one of the three secure subkeys. Data can be transferred as one large block of 512 bits or it can be transferred in blocks of 64 bits each (Figure 10). There are nine valid block selectors which are used to specify which block or blocks are to be transferred (Figure 11). As a further precaution against accidental erasure of a secure subkey, the 64-bit password of the destination subkey must be entered and match the destination subkey. If the passwords fail to match, the operation is terminated. The flow sequence is shown in Figure 12.
SCRATCHPAD READ/WRITE COMMANDS
The 512-bit read/write scratchpad of the DS1205S MultiKey is not protected by a security match code. This
021798 4/17
DS1205S
SET SECURITY MATCH Figure 5
WRITE SET PASSWORD IN COMMAND WORD (SPECIFY WHICH SECURE PARTITION)
SET SECURE DATA Figure 6
WRITE SET SECURE DATA IN COMMAND WORD (SPECIFY WHICH SECURE PARTITION AND STARTING BYTE ADDRESS)
READ I.D. FIELD FROM SECURE PARTITION (64 BITS)
READ I.D. FIELD FROM SECURE PARTITION (64 BITS)
WRITE 64 BITS OF DATA TO DS1205 (OLD I.D.) WRITE 64 BITS OF DATA TO DS1205
IS DATA = I.D?
NO
TERMINATE TRANSACTION
YES
IS DATA = PASSWORD?
NO
TERMINATE TRANSACTION
ERASE I.D. AND PASSWORD FIELD, SECURE DATA FIELD FOR SELECTED SECURE PARTITION.
YES
WRITE 64 BITS OF DATA FOR NEW I.D. FIELD DATA
WRITE DATA TO SECURE DATA FIELD (STARTING ADDRESS SPECIFIED IN COMMAND WORD)*
*Data is written to the DS1205S beginning at the specified address and continuing until either Bit 511 is written or the RST line is brought low.
WRITE 64 BITS OF DATA FOR NEW PASSWORD FIELD DATA
TERMINATE TRANSACTION
TERMINATE TRANSACTION
021798 5/17
DS1205S
GET SECURE DATA Figure 7
SET SCRATCHPAD Figure 8
WRITE SET SECURE DATA IN COMMAND WORD (SPECIFY WHICH SECURE PARTITION AND STARTING BYTE ADDRESS)
WRITE SET SCRATCHPAD IN COMMAND WORD
READ I.D. FIELD FROM SECURE PARTITION (64 BITS)
WRITE DATA BITS TO DS1205 (STARTING ADDRESS SPECIFIED IN COMMAND WORD)
WRITE 64 BITS OF DATA TO DS1205 IS BYTE 63 WRITTEN YET? NO
YES HAS RST LINE GONE LOW? OUTPUT RANDOM DATA NO
IS DATA = SECURITY MATCH?
NO
YES YES
OUTPUT SECURE DATA FIELD CONTENTS*
TERMINATE TRANSACTION
TERMINATE TRANSACTION
*Data is read from the DS1205S beginning at the specified address and continuing until either Bit 511 is read or the RST line is brought low.
021798 6/17
DS1205S
SET SCRATCHPAD Figure 9
BLOCK SELECTIONS Figure 10
BLOCK NUMBER 0 1 BYTE ADDRESS SCRATCHPAD 0-7 8-15 IN: SUBKEY 0-7(ID) 8-15 (PASSWORD) 2 16-23 16-23 (SECURED) 3 24-31 24-31 (SECURED) 4 32-39 32-39 (SECURED) 5 40-47 40-47 (SECURED)
SET GET SCRATCHPAD PARTITION IN COMMAND WORD
READ DATA BITS FROM SCRATCHPAD PARTITION (STARTING ADDRESS SPECIFIED IN COMMAND WORD)
IS BYTE 63 READ YET?
NO
6
48-55
48-55 (SECURED)
7
YES HAS RST LINE GONE LOW? NO
56-63
56-63 (SECURED)
BLOCK SELECTOR CODES FOR MOVE BLOCK COMMAND Figure 11
BLOCK # 0 1 2 SELECTOR CODE 4C69 6E64 9DB3 9A9A (H) 4C69 919B 624C 9A9A (H) 4C96 6E9B 62B3 659A (H) 4366 616B 6D43 6A6A (H) BC99 9E94 92BC 9595 (H) B369 9164 9D4C 9A65 (H) B396 6E64 9DB3 6565 (H) B396 919B 624C 6565 (H) 7F5A 5D57 517F 5656 (H)
YES
TERMINATE TRANSACTION
3 4 5 6 7 ALL BLOCKS
021798 7/17
DS1205S
MOVE BLOCK Figure 12
WRITE MOVE BLOCK IN COMMAND WORD
3-WIRE BUS
The 3-wire bus is comprised of three signals. These are the RST (reset) signal, the CLK (clock) signal, and the DQ (data) signal. All data transfers are initiated by driving the RST input high. The RST signal provides a method of terminating a data transfer. A clock cycle is a sequence of a falling edge followed by a rising edge. For data inputs, the data must be valid during the rising edge of a clock cycle. Command bits and data bits are input on the rising edge of the clock and data bits are output on the falling edge of the clock. All data transfers terminate if RST is low and the DQ pin goes to a high impedance state. When data transfers to the DS1205S are terminated by the RST signal going low, the transition of the RST going low must occur during a high level of the CLK signal. Failure to ensure that the CLK signal is high will result in the corruption of the last bit transferred. Data transfers are illustrated in Figure 13 and Figure 14 for normal modes of operation.
WRITE 64-BIT BLOCK SELECTOR CODE TO DS1205
WRITE 64-BIT PASSWORD OF DESTINATION SUBKEY
IS DATA = PARTITION PASSWORD?
NO
TERMINATE TRANSACTION
YES
TRANSFER SPECIFIED SCRATCHPAD DATA BLOCKS TO SPECIFIED PARTITION
*
ERASE ALL SCRATCHPAD MEMORY
*
TERMINATE TRANSACTION
*TRANSPARENT TO USER
021798 8/17
DS1205S
WRITE DATA TIMING DIAGRAM Figure 13
tCWH
RESET tCC tCL tR tCCH tF
CLOCK tDC tCDH DATA INPUT/OUTPUT R/W R/W tCH
R/W
READ DATA TIMING DIAGRAM Figure 14
tCWH
RESET tCC
CLOCK tDC R/W tCDD tCDZ
1-WIRE PROTOCOL
The 1-wire protocol defines the system as a single bus master system with single or multiple slaves. In all instances, the DS1205S is a slave. The bus master is typically a microcontroller. The discussion of this protocol is broken down into two topics: hardware configuration and transaction sequence.
Hardware Configuration
The 1-wire bus has only a single line by definition; it is important that each device on the bus be able to drive it at the appropriate time. To facilitate this, each device attached to the 1-wire bus must have open drain connections. The DS1205S is an open drain part with an internal circuit equivalent to that shown in Figure 15. Ideally, the bus master should also be open drain; but if this is
not feasible, two standard TTL pins can be tied together, one as an output and one as an input. When using a bus master with an open drain port, the bus requires a pullup resistor at the master end of the bus. The system bus master circuit should be equivalent to the one shown in Figure 16. The value of the pull-up resistor should be greater than 5K ohms. If the pull-up value is less, the bus may not be pulled to an adequately low state (< 0.6 volts). The idle state for the 1-wire bus is high. If, for any reason, a transaction needs to be suspended, the bus MUST be left in the idle state if the transaction is to resume. If this does not occur and the bus is left for more than 560 S, all components on the bus will be reset.
021798 9/17
DS1205S
EQUIVALENT CIRCUIT Figure 15
RX 500K ohms
Transaction Sequence
The protocol for accessing the DS1205S is as follows: Reset Presence Detect 1-wire Command Word Device Command Word Transaction/Data CRC Reset/Presence Detect - All transactions on the 1-wire bus begin with the reset sequence. The reset sequence is started by holding the data line low for 560 S. The DS1205S is designed to be held in the reset state whenever it is not connected to the bus. When it is connected to the bus, the data line is pulled high, the part is taken out of reset, and the part is ready to issue the presence detect. After detecting a high state on the data line, the DS1205S waits 15 S minimum and issues its presence detect. This presence detect is a low-going pulse that last 70 S. This response to the reset pulse lets the bus master know that the DS1205S is on the bus and is ready to operate. The presence detect helps the bus master to discriminate the communication signals from noise as the DS1205S is taken on and off the bus. Refer to the timing diagram in Figure 17. After the DS1205S has responded to the reset pulse with a presence detect, the bus master drives the bus to the idle state for a minimum of 1 S. The 1 S interval is like a frame sync. After each bit is transmitted on the bus, there is a frame strobe to sync up for the next transmission. Refer to Figure 17.
TX
100 ohm MOSFET
BUS MASTER OPEN DRAIN CIRCUIT Figure 16A
VDD Microcontroller DS5000 or 8051 equivalent Open Drain Port Pin RX TX To data connection of DS1205S 5K ohms VDD
BUS MASTER STANDARD TTL CIRCUIT Figure 16B VDD Microcontroller
TTL-Equivalent To data connection of DS1205S
Port Pins
Rx
T x
5K ohms
021798 10/17
DS1205S
RESET/PRESENCE DETECT SEQUENCE Figure 17
FIRST BIT OF 1-WIRE PROTOCOL tSYC RESET PULSE DRIVEN LOW BY HOST IDLE STATE PRESENCE DETECT DRIVEN BY 1-WIRE DEVICE
tRSTL
tPDH
tPDL
tRSTH
1-Wire I/O Commands - Once the bus master has detected a presence, it can issue one of the four different 1-wire I/O commands. These commands deal with the laser-etched ROM code which has the following format. Type ID 8 bits Unique Serial Number 48 bits CRC 8 bits
Data command the bus master can, by process of elimination, find the ID numbers of all the devices on the bus. Once this is known, the bus master can then go back and read the device type that corresponds to each ID number. The ROM search process is the repetition of a simple 3-step routine: read a bit, read the complement of the same bit, then write the desired value of that bit. The bus master performs this simple 3-step routine on each bit of the ROM. After one complete pass, the bus master knows the contents of the ROM in one device. The bus is reset and the process is repeated again, selecting a different set of bit values. The bus master controls the search according to what values are written as select bits. The following example of the ROM search process assumes four different devices are connected to the same 1-wire bus. The ROM data of the four devices is as shown: ROM1 ROM2 ROM3 ROM4 00110101... 10101010... 11110101... 00010001...
All 1-wire commands are eight bits long. A list of these commands are as follows: CCh Pass Thru Mode
This command saves time by allowing direct access to the DS1205S without identifying it by ROM ID number. This command can only be used when there is a single slave on the bus. If more than one device is present, there will be bus contention. 33h Read ROM Data This command allows the bus master to read the DS1205S's unique 48-bit ID number and CRC. This command can only be used if there is a single DS1205S on the bus. If more than one is present, there will be bus contention. 55H Match ROM Data This mode allows the bus master to single out a specific DS1205S on a multidrop bus. The bus master selects the specific slave by the ROM ID number for the transaction. This command can be used with a single or multiple device on the bus. F0h Search ROM Data When a system is initially brought up, the bus master might not know the number or types of devices on the bus. By invoking the Search ROM
The search process is as follows: 1. The bus master begins by resetting all devices present on the 1-wire bus. After this, the bus master will attempt to read the family code, serial number, and CRC value for the part. 2. The bus master will then issue the Search ROM Data command on the 1-wire bus. 3. The bus master performs two reads and receives two 0 bits. This indicates that both 1 bits and 0 bits exist as the first bit of the devices on the bus.
021798 11/17
DS1205S
4. The bus master writes a 0. This deselects ROM2 and ROM3 for the remainder of this search pass, leaving only ROM1 and ROM4 connected to the 1-wire bus. 5. The bus master performs two more reads and receives a 0 bit followed by a 1 bit. This indicates that all devices still coupled to the bus have 0's as their second ROM data bit. 6. The bus master then writes a 0 to keep both ROM1 and ROM4 coupled. 7. The bus master executes two reads and receives two 0 bits. This indicates that both 1 bits and 0 bits exist as the third bit of the ROM data of the attached devices. 8. The bus master writes a 0 bit. This deselects ROM1 leaving ROM4 as the only device still connected. 9. The bus master reads the remainder of the ROM bits for ROM4 and continues to access the part if desired. This completes the first pass and uniquely identifies one part on the 1-wire bus. At this point, the bus master repeats the process described above to determine the address of the remaining devices on the 1-wire bus by repeating steps 1 though 7. Note the following: The bus master learns the unique ID number (ROM data pattern) of one 1-wire device on each ROM Search operation. The time required to derive the part's unique ID is: 960 S + 3(8+64) X 0.06mS = 13.92mS The bus master is therefore capable of identifying 60 different 1-wire devices per second. Additionally, the data obtained from the two reads of each set of three have the following interpretations: 00 01 10 11 There are still devices attached which have conflicting bits in this position. All devices still coupled have a zero bit in this bit position. All devices still coupled have a one bit in this bit position. There are no devices attached to the 1-wire bus.
the listening mode. The bus master must then transmit the 1-wire command to the DS1205S. To transmit the first bit of the 1-wire I/O command, the master pulls the bus low for 1 S. This low-going edge informs the DS1205S that the first bit is being sent. After 1 S, the master does one of two things: 1. holds the line low for an additional 70 S to output a 0 (write a 0) or, 2. lets the bus go high for an additional 70 S (write a 1). The state of the bus during this 70 S time phase determines the value of the bit. The DS1205S will sense any rising edge during this 70 S time phase as a one. After the 70 S has lapsed, the bus master must then drive the bus high for 1 S. This is the frame sync mentioned earlier. This process is repeated until all the eight bits are transmitted. Refer to the timing diagram in Figure 18. The bus master now reads the family code identifier, followed by the data and a CRC. The read cycle is similar to the write cycle. It is started with the bus master pulling the bus low for 1 S. This informs the DS1205S that it should have data on the bus no later than the 1 S from the falling edge. After the 1 S, the bus master lets go of the bus and the DS1205S drives the bus. The slave must hold the data on the bus for an additional 14 S minimum (59 S maximum). During the DS1205S holding time, the bus master reads the state of the bus. Ideally, the bus master should read data from the bus 15 s after the falling edge. The entire cycle time for one bit lasts a minimum of 70 S (140 S maximum) from the falling edge. At the end of the cycle, the bus master drives the bus high for 1 S. Again, this is like a frame sync for the next bit. This read sequence is repeated until all the data has been read. See the timing diagram in Figure 19 for details. If for any reason the transaction needs to be terminated before all the data is read, the DS1205S must be reset. CRC Generation - To validate the transmitted data from the DS1205S, the bus master must generate a CRC value for the data as it is received. This generated value is compared to the value stored in the last eight bits of the DS1205S. The bus master computes the CRC over the 8-bit family code and all 48 ID number data bits, but NOT over the stored CRC value itself. The CRC is calculated using the following polynomial. CRC = px3 + px2 + 1 If the two CRC values match, the transmission is errorfree.
Transmitting/Receiving Data - All communications on the 1-wire bus begin with the reset and presence detect sequence. This sequence ensures the DS1205S is in
021798 12/17
DS1205S
1-WIRE WRITE TIMING Figure 18
tSYC tSLOT
WRITE 1
tLOW1
tSYC
tSLOT
WRITE 0
tLOW0
1-WIRE READ TIMING Figure 19
tSYC tSLOT
READ 1
tSU
tRDV
tSYC
tSLOT
READ 0
tSU
tRDV
021798 13/17
DS1205S
PASS-THRU MODE
A host connected to the 1-wire bus may send function commands directly to the DS1205S without preceding them with 1-wire I/O commands by using the pass-thru command (CCh). This command bypasses the serial number and consequently it can only be used when there is one DS1205S on the 1-wire bus.
1-WIRE/3-WIRE ARBITRATION
The DS1205S can utilize both the 1-wire and the 3-wire busses simultaneously. Neither input bus has priority over the other. Instead, if both inputs are being used, the signal arriving first will take precedence. More simply, if the 1-wire interface becomes active before the 3-wire interface, all communications will take place on the 1-wire bus. The 3-wire bus will be ignored in this case. The same condition occurs for the 1-wire interface if the 3-wire interface becomes active first.
021798 14/17
DS1205S
ABSOLUTE MAXIMUM RATINGS*
Voltage on any Pin Relative to Ground Operating Temperature Storage Temperature Soldering Temperature -0.5V to +7.0V -40C to +85C -55C to +125C 260C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER Logic 1 Logic 0 Supply SYMBOL VIH VIL VCC MIN 2.0 -0.3 4.5 5.0 +0.8 5.5 TYP MAX UNITS V V V
(0C to 70C)
NOTES 1 1 1
DC ELECTRICAL CHARACTERISTICS
PARAMETER Input Leakage Output Leakage Output Current @ 2.4V Output Current @ 0.4V RST Input Resistance D/Q Input Resistance CLK Input Resistance Active Current Standby Current Batt. Operate Consumption Batt. Operate Standby Current Batt. Voltage Output Supply Current SYMBOL IIL IOL IOH IOL ZRST ZDQ ZCLK ICC1 ICC2 IBAT IBATS VBAT ICCO 2.0 200 30 100 100 100 3 -1 MIN TYP
(0C to 70C, VCC = 5V + 10%)
MAX +500 +500 UNITS A A mA +1 1000 1000 1000 6 100 500 200 3.6 10 mA Kohm Kohm Kohm mA A nC nA V mA 5,6 5,6 7,8 7 1 11 NOTES
CAPACITANCE
PARAMETER Input Capacitance Output Capacitance SYMBOL CIN COUT MIN TYP MAX 5 7 UNITS pF pF
(tA= 25C)
NOTES
021798 15/17
DS1205S
AC ELECTRICAL CHARACTERISTICS
PARAMETER Data to CLK Setup CLK to Data Hold CLK to Data Delay CLK Low Time CLK High Time CLK Frequency CLK Rise & Fall RST to CLK Setup CLK to RST Hold RST Inactive Time RST to I/O High Z SYMBOL tDC tCDH tCDD tCL tCH tCLK tR,tF tCC tCCH tCWH tCDZ 1 40 250 250 250 DC MIN 35 40 TYP
(0C to 70C, VCC = 5V + 10%)
MAX UNITS ns ns 200 ns ns ns 2.0 500 MHz ns s ns ns 50 ns NOTES 2 2 2,3,4 2 2 2 2 2 2 2 2
AC ELECTRICAL CHARACTERISTICS: 1-WIRE INTERFACE
PARAMETER Time Slot Period Write 1 Low Time Write 0 Low Time Read Data Valid Read Data Setup Frame Sync Reset Low Time Reset High Time Presence Detect High Presence Detect Low SYMBOL tSLOT tLOW1 tLOW0 tRDV tSU tSYC tRSTL tRSTH tPDH tPDL MIN 70 1 70 15 1 1 560 560 15 70 TYP
(0C to 70C, VCC = 5V+ 10%)
MAX 140 15 140 UNITS s s s s s s s s 70 280 s s 9 10 NOTES
021798 16/17
DS1205S
NOTES:
1. All voltages are referenced to ground. 2. VIH = 2.0V or VIL = 0.8V with 10 ns maximum rise and fall time. 3. VOH = 2.4V and VOL = 0.4V. 4. Load capacitance = 50 pF. 5. Measured with outputs open. 6. (Normal battery backup operation) VCC1 = 5.0 Volts + 10%; VBAT = 3.0 Volts. 7. (Battery operate mode) VCCO = 3.0 Volts. 8. Per transaction (512 bits + protocol). 9. An additional reset or communication sequence cannot begin until the reset high time has expired. 10. Read data setup time refers to the time the host must pull the 1-wire pin low to read a bit. Data is guaranteed to be valid within 1 S of this falling edge and will remain valid for 14 S minimum (15 S total falling edge on 1-wire). 11. VCCO = VCCI - 0.3V
021798 17/17


▲Up To Search▲   

 
Price & Availability of DS1205S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X